.jpg)
series
|
ED3000
|
ED3100
|
ED 3800
|
Technical indicators
|
standards
|
input
|
Rated voltage and frequency
|
Single-phase 220V,Three-phase 220V,three-phase 380V 50/60HZ
|
Variable allowable value
|
Voltage: -20%~+20% Voltage unbalance: <3% frequency 50+/-5%HZ
|
output
|
Rated voltage
|
0~220V/0~380V
|
Frequency range
|
0~400HZ
|
0~400HZ
|
0~600HZ
|
The main control function
|
Modulation mode
|
Optimization space voltage vector PWM
|
Control mode
|
V/Fcontrol
|
V/FControl
Open loop vector control(SVC)
|
Standard V/F control
Vector V/F control
Separated type V/F control
vector control without PG card
|
Frequency accuracy
|
Digital setting: max frequency X + 0.01% Analog setting:
max frequency X + 0. 2%
|
Frequency resolution
|
Digital setting: 0.01 Hz; Analog setting: max frequency X 0. 1%
|
Start frequency
|
0.0Hz~10.00Hz
|
Torque rise
|
Automatic torque rise; manual torque rise:1%~ 30.0% (V/F control mode is effective only)
)
|
V/Fcurve
|
Linear V/F curve,Square V/F curve,Customized V/F curve
|
Acceleration/deceleration time
|
0.1-6000s
|
0.1-3600s
|
0.1-3600s
|
DC braking
|
Start, stop, when the action time respectively optional can be set
|
Jogging
|
Jogging frequency range: 0.1Hz ~ max frequency ;,jogging acceleration and deceleration time: 0.13600s.
|
Built-in PID
|
It is convenient for forming closed loop control system, applicable for course control like pressure and flow, etc.
|